Analysis of the reasons and solutions for inaccurate opening and closing dimensions of glass bilateral machines

Publisher: YUANBO    Time:1/22/2021 4:11:21 PM

1. Phenomena

① The opening and closing speed is slow

② Each piece of glass has different opening and closing dimensions



2. Causes and Solutions:

① Reason: The opening and closing speed switch on the operation panel is switched to slow

Solution: Switch the on/off switch to the fast up position

② Cause: There is quality or connection issue with the opening and closing encoder

Solution: Replace the encoder or replace the encoding connector

③ Cause of occurrence: The opening and closing screw nut is damaged or the linear guide slider is damaged

Solution: Replace the screw nut or linear slider

④ Cause: Rust on the opening and closing screw rod or linear guide rail

Solution: Regularly lubricate the screw rod or linear guide rail with oil

⑤ Cause: PLC, frequency converter, servo and other electrical components malfunction abnormally

Solution: Regular inspection of electrical equipment and timely handling of any abnormalities found



III. Preventive Measures:

① Before each team starts work, inspect each operating equipment and verify the status of equipment components

② Regularly inspect the encoder connector and encoder body

③ Regularly inspect and pre inspect mechanical components such as screw nuts or linear sliders, and promptly identify and handle hidden dangers

④ Timely check the oil injection equipment, regularly refuel, and regularly arrange a dedicated person to inspect electrical equipment for potential hazards